3 Pacea nr.26, 710011, Botosani
România
+40747683762
+40231522525
office@hidroplasto.de
vanzari@hidroplasto.de

INSTALLATIONSANLEITUNG

INSTALLATIONSANLEITUNG

The irreproachable operation of the supports is ensured by the correct technical installation. Load capacity can be minimized if the following instructions are not followed.

The support surface must have a suitable compression force. Ensure a suitable lateral tension force (N15 / N20).

The support should be placed in the area of ​​the corresponding static reinforcement in the concrete of the adjacent components. The edges of the supports should not be deformed in similar systematic deformations (expansion due to linear compression, displacement, torsion). The surface on which the support is mounted must be dry as a support.

If anti-skidding stability is not ensured, appropriate construction measures will be taken. Do not use glue for fastening. The supports should not be dirty for grease or similar materials.

When used in freshly cast concrete, the surrounding area must be filled with a suitable soft material (eg foam) to be attached to the adhesive tape.

Additional instructions for NEG, B1EG

Normally, the elastomeric sliding bearings will be matched to the sliding plate above (continuous hard surface). Pay attention to the deviations of the designer.

Additional instruction SD-embossed support

By using prefabricated elements, the lower joint below the substrate must be filled with soft material immediately after fitting. When used in cast concrete, the surface of the SD striped support must be protected with a solid material (eg cardboard)

The irreproachable operation of the sliding strips is ensured by the correct technical installation. The support surface must be smooth, level and clean and also free of oil traces.

For cast concrete roofs, the shuttering must be 15-20 mm taller than the top edge of the strip. On the inside walls the gypsum must be separated between the wall and the ceiling with a cut.

TG 1 A

The support surface should be very smooth, flat and clean to install the sliding foil wrapped to prevent it from running out of operation. This will use protective layers to compensate for the remaining inequalities.

TG1A + b1, TG1A + b4 and TG5POM + b4

One-piece cloths will be fitted with the garment on the underside.

TDG 27 SZ, TD 21 S

The core slides should be mounted with the core at the bottom. The tape supports must have joints that do not overlap and must be connected with adhesive tape to prevent the concrete from penetrating.

NEVER FIX WITH NAILS!

Impeccable operation is conditional on correct installation. The friction coefficient of the support is reduced if the following is not observed:

  1. The foundation must be horizontal, level and smooth.
  2. The lower protection layer should be placed in the length of the layer without overlapping. Separate structures must be bonded to the adhesive tape.
  3. The first two-layer film should be placed perpendicular to the protective layer and the second part of it.
  4. The adhesive tape should be loose on the long sides of the foil. The first foil (A) should have an opening of approx. 20 cm to be in the second foil (B) with an overlap of approx. 5 cm. The top ends as well as the joints of
  5. the long side of each sheet must be closed with adhesive tape. This procedure must be repeated for each piece of foil.
  6. The top protective layer should be placed without overlap, in the same way as the bottom. Separate layers must be bonded with adhesive tape and protected against wind gusts.